General Spectrometer Accessories
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (2)
- (5)
- (5)
- (5)
- (1)
- (14)
- (1)
- (2)
- (4)
- (1)
- (1)
- (1)
- (1)
- (1)
- (2)
- (1)
- (10)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (2)
- (3)
Filtered Search Results
Perkin Elmer US LLC Spacers for Semi-Demountable Cells - PTFE, 0.05 mm, Qty. 6
PerkinElmer supplies rectangular spacers made of either lead or teflon. These spacers come in a variety of thicknesseses, allowing you to customize the Universal Demountable Cell's path length to the experiment's requirements. Also available is a packet of Assorted Rectangular Spacers (L1270421) which includes two of each type of spacer. Please note: When rectangular windows and spacers are used, the Universal Demountable Cell becomes a Semi-Demountable Cell.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Glass Expansion RF Coil Silver for 700-ES Series Radial
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
RF Coil Silver for Agilent (Varian) 700-ES Series Radial ICP-OES. Compatible with Agilent (Varian) 700-ES Series Radial ICP-OES. The RF coil is susceptible to corrosion in the torch box, which eventually lowers the conductivity of the coil. The greater the corrosion, the larger amount of energy is needed to produce a plasma of the same power. Coils in a corroded condition, increases the stress applied to other components in the RF generating system, and can shorten the lifetime of your torch. Copper is used as the base material of most commercially available coils but different plating materials are available. Silver has the best conductance & gold the best corrosion resistance. For Gold 501907323, PTFE Coated Silver 501907325.To install your coil and ensure proper alignment, we highly recommend our re-useable RF Coil Installation Tool Kit (501907326).Glass Expansion is ISO 9001:2015 certified by AB Certification, No. AU4501-9001
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Glass Expansion Quartz Torch with 1.0mm Injector for Agilent 7700/7800/7900/8800/8900
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Quartz Torch, single-piece, 1.0 mm id tapered injector (G3280-80081), for volatile organic solvent analysis with Agilent 7700, 7800, 7850, 7900, 8800, 8900 ICP-MS. Suitable for organic applications with volatile solvents but not inert to samples containing hydrofluoric acid (HF).For volatile organic solvents, also see catalog number 50-190-6994.For samples containing HF see catalog number 30-808-4185.Glass Expansion is ISO 9001:2015 certified by AB Certification, No. AU4501-9001
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Glass Expansion Quartz Torch with 3 slots for Optima 2000/4000/5000/7000 DV
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Quartz Torch, 3-Slot demountable quartz torch standard for PerkinElmer Optima 2000/4000/5000/7000 DV Series ICP-OES (N0772005).Recommended for organic solvent applications, but not inert to samples containing hydrofluoric acid (HF).Glass Expansion is ISO 9001:2015 certified by AB Certification, No. AU4501-9001
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Glass Expansion Sapphire Injector 2.4mm for D-Torch
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Sapphire Injector with 2.4mm ID.2.4mm ID sapphire injector (50-190-7222, 31-808-3414). This sapphire injector, with 2.4 mm I.D., is for use with Spectro EOP/SOP, Axial/Radial (Modula, CIROS, Genesis, ARCOS) ICP-OES, not for ARCOS II. Sapphire injectors are ideal for silicon and HF applications.Spectro EOP/SOP, Axial/Radial (Modula, CIROS, Genesis, ARCOS) ICP-OES Injectors - Compatible with Glass Expansion Axial D-Torch 50-190-7029 (30-808-3496) and Radial D-Torch 50-190-7023 (30-808-2928). Optional Tapered Quartz Injectors are 1.8 mm 50-190-7168 (31-808-2974), 2.5 mm 50-190-7252 (31-808-3723) and 3.0mm 31-808-3724, Tapered Alumina Injectors are 1.2mm 50-190-7191 (31-808-3238), 1.8mm 50-190-7166 (31-808-2963) and 2.4mm 50-190-7214 (31-808-3388). Glass Expansion is ISO 9001:2015 certified by AB Certification, No. AU4501-9001
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Glass Expansion Nickel Sampler Cone for Thermo Scientific Element 1/Element 2/Neptune ICP-MS
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
100% Nickel Sampler Cone ¿ For Thermo/Finnigan Element 1, 2 & Neptune ICP-MS. Use for lowest Cu background, and suitable for most common applications (e.g., routine aqueous samples, <5% acid matrix, non-HF, non-organic). Not recommended for samples containing hydrofluoric acid (HF). Use a new Graphite Sampler Cone Gasket (501907717) each time the cone is re-installed, even if it¿s the same cone. Use 10x Magnifier Inspection Tool with Built-In LED Illumination (NC2042261) to inspect cone orifice condition. When not in use, keep cones stored in original packaging for protection.For lowest boron background and semiconductor applications, we recommend a platinum cone, see catalog number 501907711.For high sensitivity applications and low matrix containing samples, we recommend Nickel Jet Sampler, see catalog number 501907709.Glass Expansion is ISO 9001:2015 certified by AB Certification, No. AU4501-9001
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
MSC STL SLURRY VAC SYSTEM
5PC 30GAL 120V 124"LFT STL SLURRY VAC SYSTEM
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Perkin Elmer US LLC SeaSpray Glass Nebulizer, 2.0 mL/min, for ELAN/NexION 300/350
The SeaSpray Concentric Nebulizer is ideal for samples with high dissolved solids and offers outstanding nebulization effciency for trace level analysis. It offers freedom from clogging while nebulizing solutions near the limit of solubility of most mineral salts, and conferring signifcant sensitivity gains. All SeaSpray Nebulizers are supplied with the EzyLok argon connector.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Perkin Elmer US LLC Alumina Injector, 1.2 mm I.D. for Optima 2/4/5/7x00 DV
This Alumina Injector is for use with Optima 2x00/4x00/5x00/7x00 DV ICP-OES series instruments. Alumina injectors are corrosion-resistant to all mineral acids including HF and aqua regia. They are also used with less volatile organic solvents, e.g., xylene.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Thermo Scientific MIRA MIST NEBULIZER
Mira Mist Nebuliser; HF resistant, parallel path nebulizer intended for the analysis of; samples containing HF acid and/or samples containing high levels of; dissolved solids.; The unique parallel path design provides enhanced resistance to; blockages when running samples containing; fine particulates and dissolved solids.; The nebulizer design enables liquid aspiration over a variable flow; rate of 0.2-2.5 ml/min and is compatible with all iCAP 6000 Series; Spectrometers
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Glass Expansion PVC Pump Tube 2tag, 152mm spacing, 1.22mm ID, Red/Grey (PKT 12)
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
PVC Pump Tube 2tag 1.22mm ID Red/Gray (PKT 12).Tag Colors: Red/GrayID mm: 1.22Wall Thickness mm: 0.86OD mm: 2.94Overall Length: 455mm (152mm spacing between tags)Number of Tubes Per Pack: 12Physical Properties: Thermoplastic, PVC based material with plasticizerMaterial: Made from Tygon R3603/R3607 or equivalent.Special Properties: Inexpensive all-around tubing for general laboratory applicationsChemical Compatibility: Excellent for aqueous solutions of the following acids and concentrations, up to 35% Nitric Acid, up to 37% Hydrochloric Acid, up to 25% Hydrofluoric Acid, up to 30% Hydrogen Peroxide.Limitations: Potential leaching of plasticizersGlass Expansion is ISO 9001:2015 certified by AB Certification, No. AU4501-9001
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Glass Expansion Nickel Skimmer Cone with Copper Base for Shimadzu 2030 ICP-MS
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Nickel Skimmer Cone with Copper Base¿ For Shimadzu 2030 ICP-MS. Suitable for most common applications (e.g., routine aqueous environmental samples, <5% acid matrix, non-HF, non-organic). Not recommended for samples containing hydrofluoric acid (HF). Replace skimmer cone screws if corroded or worn (SZ5002). Use 10x Magnifier Inspection Tool with Built-In LED Illumination (NC2042261) to inspect cone orifice condition. When not in use, keep cones stored in original packaging for protection.For samples containing HF, and other highly corrosive samples where acid concentration begin to exceed 5%, we recommend a platinum cone, see catalog number 501907703. For routine samples, we recommend standard nickel skimmer, see catlog number 501907699.Use copper skimmer for standard low-cost option, see catalog number 501907698.Glass Expansion is ISO 9001:2015 certified by AB Certification, No. AU4501-9001
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Glass Expansion Skimmer Cone Interface, Standard for Thermo Scientific X Series II ICP-MS (3601320)
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Skimmer Cone Interface, Thermo X Series II (3601320) Standard skimmer cone interface for Thermo X Series II.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Perkin Elmer US LLC Standard Organics Glass Twister Spray Chamber with Helix for Optima 2x00/4x00/5x00/7x00 DV/8x00
The baffled, cyclonic Twister spray chamber has a central transfer tube, which acts as a secondary particle separator, helping separate larger aerosol particles from the sample. This reduces solvent load in the plasma without compromising detection limits. The position of the baffle is carefully controlled to ensure smooth draining and improved precision. The baffle is cut at a sharp angle so that a large cross-section of the spray chamber is sampled, ensuring representative sampling and reduced matrix effects. Although this spray chamber isn't hydrofluoric acid-resistant, precision is considered excellent and purity is considered good. Material: Borosilicate glass Volume: 50 mL Low RSD's due to highly accurate construction Application uptake range 0.2 to 3.0 mL/min Produces smaller mean droplet size than standard spray chamber Positive stop for reproducible nebulizer insertion Convenient UniFit™ drain connector
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Glass Expansion OpalMist DC Nebulizer 0.2mL/min, Includes NFT-050 UniFit Connector with 0.50mm ID x 1.3mm OD x 700mm long tubing (1 piece) and 70-803-0969 Gas Fitting with Ratchet Nebulizer connector
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
OpalMist DC Nebulizer 0.2mL/min, includes UniFit Connector with 0.50mm ID x 1.3mm OD x 700mm long tubing (1 pc) & DC Gas Fitting Type 11 with ratchet connector (1 pc). Compatible with Analytik Jena ICP-MS and Leeman.Optimum nebulizer gas flow rate is 1.0L/min & sample flow rate is 0.2mL/min. Recommended not to exceed optimum 0.2mL/min sample flow rate; however, lower gas & sample flow rates are OK. The backpressure should read ~40 psi at 1.0L/min gas flow rate. OpalMist is made from high purity PFA resulting in the lowest background & exceptional resistance to HF. Tolerates up to 15% TDS & 75um particulates.Replacement parts include P/Ns NC1625341 & 502703076.Recommended nebulizer maintenance tools are Fluka RBS25 (P/N NC9000117) & Eluo Nebulizer Cleaning Tool (P/N 501907353). When nebulizer is not in use, best to store in the provided hard plastic case.Glass Expansion is ISO 9001:2015 certified by AB Certification, No. AU4501-9001
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More